The Varec 8920 Loop Powered Transmitter is designed for terminal operators, refinery engineers, inventory managers, and EPC teams who need to connect installed float-and-tape gauges to PLC, DCS, and SCADA systems via standard 4–20 mA analog input, without replacing the mechanical gauge hardware.
Unlike battery-backed electronic transmitters that lose position on power loss until the battery is replaced, the 8920 LPT uses a battery-free absolute capacitive encoder with direct-drive gearing that retains the correct tank level reading through outages, delivering ±1/16 in (1.58 mm) accuracy across 0–120 ft (0–36 m).
The 8920 mounts directly to Varec, L&J, GSI, and Sakura float-and-tape gauges and converts float displacement to a calibrated 4–20 mA signal that feeds RTU analog input modules, PLC I/O cards, and DCS terminations with no signal conditioning or protocol conversion. An optional second 4–20 mA loop adds temperature via 3-wire RTD, and 2 or 4 SPDT cam-operated limit switches provide independent high- and low-level alarm relays.
Loop-powered DC (20–48 VDC, two-wire) and active AC (85–305 VAC) variants fit both modern and legacy installations. A capacitive-touch LCD handles tank-side configuration, scaling, and diagnostics in an explosion-proof aluminum IP66/NEMA 4 enclosure with cFMus, ATEX, IECEx, and UKEx approvals.
An absolute capacitive encoder with direct-drive gearing retains the correct level position through power interruptions without batteries, backup memory, or additional hardware.
Direct-mount compatibility with Varec, L&J, GSI, and Sakura float-and-tape gauges turns installed mechanical gauging into a 4–20 mA field instrument with minimal mechanical rework.
A primary 4–20 mA level loop, with an optional second loop for RTD-based temperature, delivers complete tank data through a single tank-side instrument.
Two or four cam-operated SPDT limit switches with independently adjustable dwell and set points provide hardwired relay outputs for high-high, high, low, low-low alarms.
A tank-side capacitive-touch LCD supports level reading, output scaling, and parameter configuration without a laptop, handheld, or external calibration tool.
Impregnated aluminum IP66 / NEMA 4 enclosure carries cFMus, ATEX, IECEx, and UKEx approvals for hazardous-area installation across North America, Europe, and the UK.
±1/16 in (1.58 mm) accuracy; ~0.16% full-scale repeatability
0–120 ft (0–36 m); limit switch range up to 100 ft (30 m)
Primary 4–20 mA (level); optional 4–20 mA (temperature); HART pending
3-wire RTD (e.g., PT100)
2 or 4 SPDT cam-operated switches; adjustable dwell and independent set points
20–48 VDC loop-powered (passive) or 85–305 VAC (active)
Varec, L&J, GSI, Sakura float-and-tape gauges (direct mount)
−25 to +73 °C (cFMus Div 1, external display only); −40 to +73 °C (cFMus Zone 1 / ATEX / IECEx / UKEx, Type 4); −40 to +85 °C (cFMus Zone 1 / ATEX / IECEx / UKEx, IP66); 0–95% RH non-condensing
Explosion-proof impregnated aluminum; IP66 / NEMA 4; 2–3 × ¾″ NPT entries
Approx. 17 lb (7.7 kg); 13.75″ W × 7.5″ H × 15″ D (350 × 190 × 380 mm)
Capacitive-touch LCD, tank-side
cFMus, ATEX, IECEx, UKEx
PLC / DCS / SCADA via 4–20 mA; FuelsManager® via RTU analog input
If you have questions not covered here, please contact the Cognesense support team for assistance.
Contact Us ↵Yes. The base unit operates on 20–48 VDC loop power as a two-wire passive device. An AC-powered active variant (85–305 VAC) is available when loop power is not available at the gauge location.
Yes. Order the dual-loop variant to output level and temperature on separate 4–20 mA loops from a single tank-side unit. A 3-wire RTD input (e.g., PT100) is on-board.
The absolute capacitive encoder mechanically retains the correct level position through power interruptions — no batteries, no backup memory. When power returns, the 4–20 mA output matches the tank level.
Select 2 or 4 SPDT cam-operated limit switches; each has independently adjustable dwell and set points for high-high, high, low, and low-low levels.
The 8920 direct-mounts to Varec, L&J, GSI, and Sakura float-and-tape gauges, converting the mechanical measurement to a 4–20 mA digital output without replacing the gauge.
cFMus, ATEX, IECEx, and UKEx approvals cover Class I Division 1 and Zone 1 hazardous locations across North America, Europe, and the UK. The enclosure carries IP66 / NEMA 4 ingress protection. Consult the current datasheet for exact certification codes.
The 8920 direct-mounts on 2500 and 2520 ATG float-and-tape gauges, converting their mechanical float position into a calibrated 4–20 mA level signal (and optionally a temperature loop) for PLC, DCS, and RTU integration. That combination is the common modernization path — keep the proven mechanical ATG, add the 8920 for digital output, then feed a Varec 8810 RTU or 9810 miniRTU into FuelsManager® and SCADA.
HART support is listed as pending. Confirm availability against the current datasheet before specifying HART output on a new project.
With over a century of tank gauging heritage, Cognesense brings the Varec 8920 Loop Powered Transmitter to terminals, refineries, chemical plants, and aviation fuel farms standardizing analog level signaling across installed float-and-tape fleets. Battery-free absolute encoding retains position through outages, dual 4–20 mA loops deliver level and temperature on one instrument, and direct-mount compatibility with Varec, L&J, GSI, and Sakura gauges turns proven mechanical gauging into modern PLC, DCS, and SCADA inputs, trusted wherever you need to measure, monitor, and protect what matters most.