Biogas cover equipment encompasses the mechanical and monitoring devices installed at the interface of fixed and floating anaerobic digester covers, including egg-shaped digesters and low-pressure gas holders. These instruments manage operating pressure and vacuum, prevent flame flashback, provide safe personnel access, and protect cover structures during normal operation and upset conditions.
Conservation vents and emergency vents set the pressure and vacuum thresholds that protect membrane and rigid covers from structural overload. Flame arresters, in plate element, end-of-line, and inline deflagration configurations, interrupt flame propagation at cover openings and connected piping. Safety selector valves route or isolate gas flow paths. Manway covers, gauge hatches, and viewport covers provide gas-tight access for maintenance without releasing biogas to atmosphere.
The MCG 2000MAX level transmitter provides continuous cover position monitoring, while the MCG 5200 wireless system relays pressure, alarm, and position data to remote displays without new cabling through the cover structure. All devices are built for wet, corrosive, and sulfide-containing biogas environments with metallic construction and biogas-compatible seals. The Expanda-Seal™ design on manway covers minimizes fugitive emissions at the cover interface.
Biogas cover equipment is organized by device role rather than a single product family, because each digester cover requires multiple coordinated functions working in parallel. Cover protection devices manage normal operating conditions and provide continuous measurement. Safety and isolation devices enable controlled gas routing and remote alarm notification. Cover access and inspection devices provide physical access and last-resort overpressure protection. Flame protection devices provide flame front interruption at every opening in the cover gas space. All device types are selected and specified together as a coordinated cover-level solution, because a gap in any function creates an unacceptable risk in continuous biogas service.
Biogas cover equipment is specified when a digester or gas holder cover requires integrated protection, access, and monitoring as a complete engineered system:
A single cover may require conservation vents, flame arresters, emergency vents, manways, and monitoring in a coordinated package. Shand & Jurs provides the complete device set from one source, simplifying specification, procurement, and installation.
All devices are engineered for wet, corrosive, and sulfide-containing gas environments that degrade standard hardware. Metallic construction and biogas-compatible sealing materials are standard, not optional.
Gas-tight manway covers, including the Expanda-Seal™ design, allow personnel access and inspection without venting the cover gas space to atmosphere, protecting both emissions performance and operator safety.
The MCG 5200 wireless monitoring and alarm system and WirelessHART adapter eliminate the need for new cable runs to cover-mounted instruments, reducing installation cost and complexity on existing and new digester structures.
The MCG 2000MAX level transmitter integrates cover or liquid level measurement alongside mechanical protection devices, providing a single cover-level data stream for SCADA and control system integration.
Three flame arrester configurations, plate element at cover openings, end-of-line for external sources, and inline deflagration for connected piping, address every ignition pathway at a single digester cover.
| Device Role | Product Family | Best Used When… | Models |
|---|---|---|---|
|
Cover Protection
|
Pressure & Vacuum Conservation Vents | Normal operating pressure and vacuum protection is required | 94020, 94021, 94022 |
|
Cover Protection
|
Level Transmitters | Continuous cover or tank level measurement is required | MCG 2000MAX + 92021/2500 |
|
Safety & Isolation
|
Safety Selector Valves | Safe routing or isolation of gas flow paths is required | 97190 |
|
Safety & Isolation
|
Wireless Monitoring & Alarm Systems | Remote monitoring and alarm notification is required | MCG 5200, WirelessHART Adapter, MCG 1097 |
|
Cover Access & Inspection
|
Viewport Inspection Covers | Visual inspection of cover interior is required | 97187 |
|
Cover Access & Inspection
|
Gauge Hatches | Manual access for inspection or gauging is required | 95021 |
|
Cover Access & Inspection
|
Manway Covers | Personnel access to the digester or cover is required | 95210, 95220 |
|
Cover Access & Inspection
|
Emergency Vents / Manway Covers | Emergency overpressure protection is required at the cover | 94210, 94225 |
|
Flame Protection
|
Plate Element Flame Arresters | Flame protection is required at cover-mounted openings | 94309 |
|
Flame Protection
|
End-of-Line Flame Arresters | Protection against external ignition sources is required | 94306 |
|
Flame Protection
|
Inline Deflagration Flame Arresters | Deflagration protection is required in cover-connected piping | 94406, 94407 |
|
Cover Position
|
Cover Position Indicators | Visual or mechanical confirmation of cover position is required | 92021/ 2500 |
Biogas-service conservation vents providing normal operating pressure and vacuum protection at digester covers, set to defined thresholds in multiple connection sizes.
Continuous level transmitter for cover or tank position monitoring in biogas service, with analog output for SCADA, FuelsManager®, or Clairvoyance integration.
Gas-tight manway covers providing safe personnel access to digester interiors without releasing biogas to atmosphere, supporting emissions compliance.